Ventilation involves managing the intake, circulation and extraction of air in accordance with the occupancy and use of the space. A well-integrated strategy complements air conditioning and air quality.
Multi-zone controlled mechanical ventilation (CMV) with heat recovery to prevent energy wastage.

A meeting room, a hotel room and a technical area all have different requirements. The design takes into account people, activities, timings and physical constraints.
Ventilation should renew the air without creating draughts or an unnecessary thermal load. Energy control and recovery can be assessed on a case-by-case basis.
Filters, flow rates and sensors should be checked regularly. AIRQIA advocates an approach whereby the installation remains easy to understand after handover.
Ventilation is the process of replacing indoor air, loaded with moisture, carbon dioxide and odours, with outdoor air in an adequate amount. In a well-insulated, airtight building, opening windows now and then rarely does the job, and that is where controlled mechanical ventilation becomes relevant. The aim is to renew the air continuously and predictably, without depending on the behaviour of the people using the space.
Every space has different needs. A meeting room fills and empties through the day, a bedroom needs quiet renewal and a technical area may call for local extraction. Sizing should therefore consider the number of people, their activities, schedules and the physical constraints of the building, rather than floor area alone. A well-sized system keeps these different uses comfortable without wasting energy.
Renewing air has an energy cost, because outdoor air arrives colder in winter and warmer in summer. Systems with heat recovery transfer part of the energy from the outgoing air to the incoming air, reducing that penalty. Air conditioning and ventilation should be planned together so that airflows, filters and controls work in a coordinated way. The right balance depends on climate, building use and the equipment already installed.
Good ventilation is kept up with clean filters, verified airflows and accessible technical documentation. Without that follow-up, performance degrades quietly. To explore technical criteria, see REHVA, the federation of European HVAC associations, and read how indoor air quality relates to air renewal. If you have a project, talk to the AIRQIA team. Each building needs its own assessment.
Tell us about the background, the objectives and the deadline. The AIRQIA team will help you determine the most appropriate technical approach.
Utilizamos cookies necessários para o funcionamento do site. Com a sua escolha, podemos também usar cookies opcionais para compreender a utilização e melhorar a experiência. Pode aceitar, rejeitar ou personalizar as preferências.
Escolha as categorias opcionais. Pode alterar esta decisão a qualquer momento.
Permitem o funcionamento básico, a segurança e a memorização das preferências de cookies.
Permitem recordar dados de identificação quando deixa um comentário, se esta funcionalidade for utilizada.
Ajudam a compreender a utilização do website e a melhorar conteúdos e navegação, quando autoriza esta categoria.
Mede a utilização do website para ajudar a melhorar conteúdos e navegação. A recolha de dados de análise depende das suas preferências de cookies.
Serviço: policies.google.com (opens in a new window)
Consulte a nossa Política de Cookies e a Privacy Policy.
